am64x/am243x: Endat: Update documentation
- Add Heidenhain Test cases - Add reference and links for Boosterpack in EnDat, HDSL and Tamagawa documentation Fixes: PINDSW-6687, PINDSW-6553 Signed-off-by: Achala Ram <a-ram@ti.com>
This commit is contained in:
parent
af61f50a46
commit
800d9c5a4d
@ -369,10 +369,21 @@ earlier SDKs.
|
||||
<th> Additional Remarks
|
||||
</tr>
|
||||
<tr>
|
||||
<td> Position Sense EnDat
|
||||
<td> \ref endat_init
|
||||
<td> Added api parameter
|
||||
<td> void* pruss_iep
|
||||
</tr>
|
||||
<tr>
|
||||
<td> Position Sense EnDat
|
||||
<td> Structure: endat_priv
|
||||
<td> Added variables: pruss_iep, cmp3, cmp5 and cmp6
|
||||
<td>
|
||||
<td>
|
||||
<td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td> Position Sense EnDat
|
||||
<td> Structure: cmd_supplement
|
||||
<td> Added variables: cmp3, cmp5 and cmp6
|
||||
<td>
|
||||
</tr>
|
||||
</table>
|
||||
|
||||
|
||||
@ -62,7 +62,7 @@ Following section describes the Example implementation of EnDat on ARM(R5F).
|
||||
<th>Folder/Files
|
||||
<th>Description
|
||||
</tr>
|
||||
<tr><td colspan="2" bgcolor=#F0F0F0> ${SDK_INSTALL_PATH}/examples/motor_control/endat_diagnostic</td></tr>
|
||||
<tr><td colspan="2" bgcolor=#F0F0F0> ${SDK_INSTALL_PATH}/examples/position_sense/endat_diagnostic</td></tr>
|
||||
<tr>
|
||||
<td>endat_diagnostic.c</td>
|
||||
<td>EnDAT diagnostic application</td>
|
||||
@ -86,7 +86,7 @@ Following section describes the Example implementation of EnDat on ARM(R5F).
|
||||
---------------|-----------
|
||||
CPU + OS | r5fss0-0 freertos
|
||||
ICSSG | ICSSG0
|
||||
PRU | PRU1
|
||||
PRU | PRU1, TXPRU1 and RTUPRU1
|
||||
Toolchain | ti-arm-clang
|
||||
Board | @VAR_BOARD_NAME_LOWER
|
||||
Example folder | examples/motorcontrol/endat_example
|
||||
@ -99,7 +99,7 @@ Following section describes the Example implementation of EnDat on ARM(R5F).
|
||||
---------------|-----------
|
||||
CPU + OS | r5fss0-0 freertos
|
||||
ICSSG | ICSSG0
|
||||
PRU | PRU1
|
||||
PRU | PRU1, TXPRU1 and RTUPRU1
|
||||
Toolchain | ti-arm-clang
|
||||
Board | @VAR_BOARD_NAME_LOWER, @VAR_LP_BOARD_NAME_LOWER
|
||||
Example folder | examples/motorcontrol/endat_example
|
||||
@ -120,8 +120,8 @@ Other than the basic EVM setup mentioned in \htmllink{@VAR_MCU_SDK_DOCS_PATH/EVM
|
||||
### Hardware Prerequisities for Booster Pack
|
||||
|
||||
- EnDat encoder
|
||||
- AM243x-LP board
|
||||
- BP-AM2BLDCSERVO
|
||||
- AM243x-LP board
|
||||
- BP-AM2BLDCSERVO, https://www.ti.com/tool/BP-AM2BLDCSERVO
|
||||
\endcond
|
||||
|
||||
## Hardware Setup
|
||||
@ -222,389 +222,571 @@ Shown below is a sample output when the application is run:
|
||||
|
||||
<table>
|
||||
<tr>
|
||||
<th style="width:4%">S.No</th>
|
||||
<th>Test detail
|
||||
<th>Steps
|
||||
<th>Pass/fail crieteria
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To check position value</td>
|
||||
<td style="text-align: center">1.</td>
|
||||
<td style="text-align: center">To check position value</td>
|
||||
<td>1. Enter 1 to select "Encoder send position values"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To receive encoder's operating parameters(error messege)</td>
|
||||
<td rowspan="4" style="text-align: center">2.</td>
|
||||
<td rowspan="4" style="text-align: center">To receive encoder's operating parameters (Error Message)</td>
|
||||
<td>1. Enter 2 to select "Selection of memory area"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "B9" in MRS code to select "Operating parameters"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 4 to select "Encoder to send parameter"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Error message"</td>
|
||||
<td>Crc success </td>
|
||||
<td>4. Enter 00 in "parameter address" for selecting "Error message"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To receive encoder's manufacture parameters for Endat 2.2</td>
|
||||
<td rowspan="4" style="text-align: center">3.</td>
|
||||
<td rowspan="4" style="text-align: center">To receive encoder's operating parameters (Warning message)</td>
|
||||
<td>1. Enter 2 to select "Selection of memory area"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "BD" in MRS code to select "Parameters of encoder manufacturer for Endat 2.2"</td>
|
||||
<td>Crc success </td>
|
||||
<td>2. Enter "B9" in MRS code to select "Operating parameters"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 4 to select "Encoder to send parameter"</td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Status of additional info"</td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To set values to encoder's operating parameters (error message)</td>
|
||||
<td>4. Enter 01 in "parameter address" for selecting "Error message"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="4" style="text-align: center">4.</td>
|
||||
<td rowspan="4" style="text-align: center">To receive encoder's manufacture parameters for Endat 2.2</td>
|
||||
<td>1. Enter 2 to select "Selection of memory area"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. Enter "BD" in MRS code to select "Parameters of encoder manufacturer for Endat 2.2"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>3. Enter 4 to select "Encoder to send parameter"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Status of additional info 1"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="5" style="text-align: center">5.</td>
|
||||
<td rowspan="5" style="text-align: center">To set values to encoder's operating parameters (Clear error message)</td>
|
||||
<td>1. Enter 2 to select "Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "B9" in MRS code to select "Operating parameters"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 3 to select "Encoder to receive parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Error message"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>5. Enter 0 in "parameter value" for seting value in " Error message"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To set values to encoder's manufacturing parameters for Endat 2.2(Status of additional info)</td>
|
||||
<td rowspan="5" style="text-align: center">6.</td>
|
||||
<td rowspan="5" style="text-align: center">To set values to encoder's operating parameters (Clear warning message)</td>
|
||||
<td>1. Enter 2 to select "Selection of memory area"</td>
|
||||
<td></td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "BD" in MRS code to select "Parameters of encoder manufacturer for Endat 2.2"</td>
|
||||
<td>Crc success </td>
|
||||
<td>2. Enter "B9" in MRS code to select "Operating parameters"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 3 to select "Encoder to receive parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>4. Enter 01 in "parameter address" for selecting "Error message"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Status of additional info"</td>
|
||||
<td>5. Enter 0 in "parameter value" for seting value in " Error message"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="8" style="text-align: center">7.</td>
|
||||
<td rowspan="8" style="text-align: center">To set values to encoder's manufacturing parameters for Endat 2.2(Status of additional info)</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>5. Enter 0 in "parameter value" for seting value in " Status of additional info"</td>
|
||||
<td>Crc success </td>
|
||||
<td>2. Enter "45" in MRS code to select "Parameters of encoder manufacturer for Endat 2.2"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To reset encoder</td>
|
||||
<td>3. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>4. Enter "BD" in MRS code to select "Memory parameter (LSB)" of Additional Information 1</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>5. Enter 10 to select "Encoder send position values + Additional Information(s) and receive parameter"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>6. Enter 0 in "parameter address" for selecting "Status of additional info"</td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>7. Enter 1235 (or any 2 byte value) in "parameter value" for seting value in " Status of additional info"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>8. Enter 8 to select "Encoder send position values + Additional Information(s)"<br>  <b>Note: Write is not permenant. When read again using Command 11, encoder will return the default value</b></td>
|
||||
<td style="text-align: center">Values followed by 0x45 represents last byte of the data received by encoder<br> Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td style="text-align: center">8.</td>
|
||||
<td style="text-align: center">To reset encoder</td>
|
||||
<td>1. Enter 5 to select "Encoder receive reset"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To receive test values from encoder with port address "0"</td>
|
||||
<td rowspan="3" style="text-align: center">9.</td>
|
||||
<td rowspan="3" style="text-align: center">To receive test values from encoder with port address "0"</td>
|
||||
<td>1. Enter 7 to select "Encoder receive test command"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter 0 in "enter port address" </td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 6 to select "Encoder send test values"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To receive test values from encoder with port address "E" </td>
|
||||
<td rowspan="3" style="text-align: center">10.</td>
|
||||
<td rowspan="3" style="text-align: center">To receive test values from encoder with port address "E" </td>
|
||||
<td>1. Enter 7 to select "Encoder receive test command"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "E" in "enter port address" </td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 6 to select "Encoder send test values"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To check position value with aditional info.</td>
|
||||
<td>1. Enter 8 to select "Encoder send position values + AI(s)"</td>
|
||||
<td>Crc success </td>
|
||||
<td rowspan="5" style="text-align: center">11.</td>
|
||||
<td rowspan="5" style="text-align: center">To check position value with aditional info.</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To receive encoder's operating parameters(error messege)
|
||||
<td>2. Enter "47" in MRS code to select "Acknowledge MRS code" of Additional Information 1</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>3. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>4. Enter "56" in MRS code to select "Asynchronous Position value word 1 LSB" of Additional Information 2</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>5. Enter 8 to select "Encoder send position values + Additional Information(s)"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="7" style="text-align: center">12.</td>
|
||||
<td rowspan="7" style="text-align: center">To receive encoder's operating parameters(error messege)
|
||||
+receive position value with additional info
|
||||
</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + AI(s) and Selection of memory area"</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "B9" in MRS code to select "Operating parameters"</td>
|
||||
<td>Crc success </td>
|
||||
<td>2. Enter "45" in MRS code to select "Memory parameter (LSB)" of Additional Information 1</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 11 to select "Encoder send position values + AI(s) and send parameter"</td>
|
||||
<td>3. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Error message"</td>
|
||||
<td>Crc success</td>
|
||||
<td>4. Enter "B9" in MRS code to select "Operating parameters"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To receive encoder's manufacture parameters
|
||||
<td>5. Enter 11 to select "Encoder send position values + Additional Information(s) and send parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>6. Enter 0 in "parameter address" for selecting "Error message"</td>
|
||||
<td style="text-align: center">CRC success</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>7. Enter 8 to select "Encoder send position values + Additional Information(s)"</td>
|
||||
<td style="text-align: center">CRC success</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="7" style="text-align: center">13.</td>
|
||||
<td rowspan="7" style="text-align: center">To receive encoder's manufacture parameters
|
||||
for Endat 2.2 +receive position value with additional info
|
||||
<td>1. Enter 9 to select "Encoder send position values + AI(s) and Selection of memory area"</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "BD" in MRS code to select "Parameters of encoder manufacturer for Endat 2.2"</td>
|
||||
<td>Crc success </td>
|
||||
<td>2. Enter "45" in MRS code to select "Memory parameter (LSB)" of Additional Information 1</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 11 to select "Encoder send position values + AI(s) and send parameter"</td>
|
||||
<td>3. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Status of additional info"</td>
|
||||
<td>Crc success</td>
|
||||
<td>4. Enter "BD" in MRS code to select "Parameters of encoder manufacturer for Endat 2.2"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To set values to encoder's operating parameters (error message)
|
||||
<td>5. Enter 11 to select "Encoder send position values + Additional Information(s) and send parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>6. Enter 0 in "parameter address" for selecting "Status of additional info 1"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>7. Enter 8 to select "Encoder send position values + Additional Information(s)"</td>
|
||||
<td style="text-align: center">CRC success</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="5" style="text-align: center">14.</td>
|
||||
<td rowspan="5" style="text-align: center">To acknowledge MRS code for Endat 2.2
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. Enter "47" in MRS code to select "Acknowledge MRS code" of Additional Information 1</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>3. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>4. Enter "BD" or any other valid MRS code </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>5. Enter 8 to select "Encoder send position values + Additional Information(s)"</td>
|
||||
<td style="text-align: center">Additional Information 1:0x47bd00<br>    (for MRS code = BD) </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="5" style="text-align: center">15.</td>
|
||||
<td rowspan="5" style="text-align: center">To set values to encoder's operating parameters (error message)
|
||||
+receive position value with additional info
|
||||
<td>1. Enter 9 to select "Encoder send position values + AI(s) and Selection of memory area"</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "B9" in MRS code to select "Operating parameters"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 10 to select "Encoder send position values + AI(s) and receive parameter"</td>
|
||||
<td>3. Enter 10 to select "Encoder send position values + Additional Information(s) and receive parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Error message"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>5. Enter 0 in "parameter value" for seting value in " Error message"</td>
|
||||
<td>Crc success</td>
|
||||
<td>5. Enter 0 in "parameter value" for seting value in "Error message"</td>
|
||||
<td style="text-align: center">CRC success</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To set values to encoder's manufacturing parameters for Endat 2.2(Status of additional info)
|
||||
<td rowspan="5" style="text-align: center">16.</td>
|
||||
<td rowspan="5" style="text-align: center">To set values to encoder's manufacturing parameters for Endat 2.2(Status of additional info)
|
||||
+receive position value with additional info
|
||||
</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + AI(s) and Selection of memory area"</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter "BD" in MRS code to select "Parameters of encoder manufacturer for Endat 2.2"</td>
|
||||
<td>Crc success </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 10 to select "Encoder send position values + AI(s) and receive parameter"</td>
|
||||
<td>3. Enter 10 to select "Encoder send position values + Additional Information(s) and receive parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Enter 0 in "parameter address" for selecting "Status of additional info"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>5. Enter 0 in "parameter value" for seting value in " Status of additional info"</td>
|
||||
<td>Crc success</td>
|
||||
<td style="text-align: center">CRC success</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To reset encoder +receive position value with additional info</td>
|
||||
<td>1. Enter 12 to select "Encoder send position values + AI(s) and receive error reset"</td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>1. Enter 14 to select "Encoder receive communication command"</td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter ______in "enter encoder address" </td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter _____ in "instruction hex value"</td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>1. Enter 14 to select "Encoder receive communication command"</td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter ______in "enter encoder address" </td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter _____ in "instruction hex value"</td>
|
||||
<td>Crc success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>Configure Clock </td>
|
||||
<td>1. Enter 100 to select "configure clock"</td>
|
||||
<td>Crc success(Tested up to 8MHz)</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter ___ for clock frequency(in Hz)</td>
|
||||
<td rowspan="7" style="text-align: center">17.</td>
|
||||
<td rowspan="7" style="text-align: center">To receive encoder's OEM (Original Equipment Manufacturer) data </td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>Simulate motor control 2.1 position loop</td>
|
||||
<td>2. Enter "45" in MRS code to select "Memory parameter (LSB)" of Additional Information 1</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>3. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>4. Enter A9 (or AB or AD) in MRS code to select the OEM memory</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>5. Enter 11 to select "Encoder send position values + Additional Information(s) and send parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>6. Enter 40 in "parameter address" </td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>7. Enter 8 to select "Encoder send position values + Additional Information(s)"</td>
|
||||
<td style="text-align: center">CRC success</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="5" style="text-align: center">18.</td>
|
||||
<td rowspan="5" style="text-align: center">To set values in OEM memory area </td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. Enter "A9" in MRS code to select "Operating parameters"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>3. Enter 10 to select "Encoder send position values + Additional Information(s) and receive parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>4. Enter 40 in "parameter address" </td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>5. Enter E9 in "parameter value"</td>
|
||||
<td style="text-align: center">CRC success</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="7" style="text-align: center">19.</td>
|
||||
<td rowspan="7" style="text-align: center">To reset encoder +receive position value with additional info</td>
|
||||
<td>1. Enter 12 to select "Encoder send position values + Additional Information(s) and receive error reset"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>1. Enter 14 to select "Encoder receive communication command"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. Enter ______in "enter encoder address" </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>3. Enter _____ in "instruction hex value"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>1. Enter 14 to select "Encoder receive communication command"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. Enter ______in "enter encoder address" </td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>3. Enter _____ in "instruction hex value"</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="2" style="text-align: center">20.</td>
|
||||
<td rowspan="2" style="text-align: center">Configure Clock </td>
|
||||
<td>1. Enter 100 to select "configure clock"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. Enter ___ for clock frequency(in Hz)</td>
|
||||
<td style="text-align: center">CRC success(Tested up to 8MHz)</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="3" style="text-align: center">21.</td>
|
||||
<td rowspan="3" style="text-align: center">Simulate motor control 2.1 position loop</td>
|
||||
<td>1. Enter 101 to select "Simulate motor control 2.1 position loop"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter 10000 to select "clock frequency"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Rotate the rotor of motor and see the changes in Position value on UART</td>
|
||||
<td>Position Values are changing when rotor moves </td>
|
||||
<td style="text-align: center">Position Values are changing when rotor moves </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>Toggle raw data display</td>
|
||||
<td rowspan="2" style="text-align: center">22.</td>
|
||||
<td rowspan="2" style="text-align: center">Toggle raw data display</td>
|
||||
<td>1. Enter 102 to select "Toggle raw data display"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter 1 to select "Encoder send position value"</td>
|
||||
<td>raw data can be displayed </td>
|
||||
<td style="text-align: center">raw data can be displayed </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>Configure TST delay</td>
|
||||
<td style="text-align: center">23.</td>
|
||||
<td style="text-align: center">Configure TST delay</td>
|
||||
<td></td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>Start continous mode</td>
|
||||
<td>1. Enter 104 to select "Start continous mode"</td>
|
||||
<td rowspan="2" style="text-align: center">24.</td>
|
||||
<td rowspan="2" style="text-align: center">Start continuous mode</td>
|
||||
<td>1. Enter 104 to select "Start continuous mode"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Rotate the rotor of motor and see the changes in Position value on UART</td>
|
||||
<td>Position Values are changing when rotor moves </td>
|
||||
<td style="text-align: center">Position Values are changing when rotor moves </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>Configure rx arm counter</td>
|
||||
<td rowspan="3" style="text-align: center">25.</td>
|
||||
<td rowspan="3" style="text-align: center">Configure rx arm counter</td>
|
||||
<td>1. Enter 105 to select "Configure rx arm counter" </td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter 0 to select channel 0(only for multi channel configuration) </td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter ___ to "select time in ns"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>configure rx clock disable time</td>
|
||||
<td rowspan="3" style="text-align: center">26.</td>
|
||||
<td rowspan="3" style="text-align: center">configure rx clock disable time</td>
|
||||
<td>1. Enter 106 to select "configure rx clock disable time"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter 0 to select channel 0(only for multi channel configuration)</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter ___ to "select time in ns"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>Simulate motor control 2.2 position loop(safety)</td>
|
||||
<td rowspan="3" style="text-align: center">27.</td>
|
||||
<td rowspan="3" style="text-align: center">Simulate motor control 2.2 position loop(safety)</td>
|
||||
<td>1. Enter 107 to select "Simulate motor control 2.2 position loop"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>3. Enter 10000 to select "clock frequency"</td>
|
||||
<td>2. Enter 10000 to select "clock frequency"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>4. Rotate the rotor of motor and see the changes in Position value on UART</td>
|
||||
<td>Position Values are changing when rotor moves </td>
|
||||
<td>3. Rotate the rotor of motor and see the changes in Position value on UART</td>
|
||||
<td style="text-align: center">Position Values are changing when rotor moves </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>Configure propogation delay(td)</td>
|
||||
<td rowspan="2" style="text-align: center">28.</td>
|
||||
<td rowspan="2" style="text-align: center">Configure propogation delay(td)</td>
|
||||
<td>1. Enter 108 to select configure propagation delay </td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter 0 to select channel 0(only for multi channel configuration)</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>To read Recovery Time</td>
|
||||
<td>1. Enter 8 to select "Encoder send position values + AI(s)" </td>
|
||||
<td>Crc Success </td>
|
||||
<td rowspan="5" style="text-align: center">29.</td>
|
||||
<td rowspan="5" style="text-align: center">Configure Recovery time (tr) using EnDat 2.2 mode transmission</td>
|
||||
<td>1. Enter 9 to select "Encoder send position values + Additional Information(s) and Selection of memory area" </td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. Enter "B9" in MRS code to select "Operating parameters"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>3. Enter 10 to select "Encoder send position values + Additional Information(s) and receive parameter"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>4. Enter 03 in "parameter address" for selecting "Initializing the functions"</td>
|
||||
<td> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>5. Enter 01 in "parameter value" for selecting low recovery time<br>               or <br> Enter 02 in "parameter value" for selecting high recovery time</td>
|
||||
<td style="text-align: center">CRC success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="2" style="text-align: center">30.</td>
|
||||
<td rowspan="2" style="text-align: center">To read Recovery Time</td>
|
||||
<td>1. Enter 8 to select "Encoder send position values + Additional Information(s)" </td>
|
||||
<td style="text-align: center">CRC Success </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td></td>
|
||||
<td>2. Enter 110 for read recovery time from DMEM </td>
|
||||
<td> Recovery Time is set to 1.25 us <= RT <= 3.75us or 10 us <= RT <= 30 us</td>
|
||||
<td style="text-align: center">Recovery Time is set to 1.25 us <= RT <= 3.75us or 10 us <= RT <= 30 us</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="2" style="text-align: center">31.</td>
|
||||
<td rowspan="2" style="text-align: center">To test periodic continuous mode</td>
|
||||
<td>1. Enter 200 to enable periodic mode </td>
|
||||
<td style="text-align: center"> </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. Enter 5000 (in ns) for position read time </td>
|
||||
<td style="text-align: center">Position Values are changing when rotor moves </td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td rowspan="2" style="text-align: center">32.</td>
|
||||
<td rowspan="2" style="text-align: center">Long term test</td>
|
||||
<td>1. Enter 111 to enable Long time continuous mode </td>
|
||||
<td></td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>2. press enter to stop the long term test</td>
|
||||
<td style="text-align: center">The result shows the number of position command sent and the number of CRC failures received</td>
|
||||
</tr>
|
||||
</table>
|
||||
@ -93,7 +93,7 @@ Other than the basic EVM setup mentioned in \htmllink{@VAR_MCU_SDK_DOCS_PATH/EVM
|
||||
|
||||
- HDSL encoder
|
||||
- AM243x-LP board
|
||||
- BP-AM2BLDCSERVO
|
||||
- BP-AM2BLDCSERVO, https://www.ti.com/tool/BP-AM2BLDCSERVO
|
||||
\endcond
|
||||
|
||||
|
||||
|
||||
@ -95,7 +95,7 @@ Other than the basic EVM setup mentioned in \htmllink{@VAR_MCU_SDK_DOCS_PATH/EVM
|
||||
|
||||
- Tamagawa encoder
|
||||
- AM243x-LP board
|
||||
- BP-AM2BLDCSERVO
|
||||
- BP-AM2BLDCSERVO, https://www.ti.com/tool/BP-AM2BLDCSERVO
|
||||
\endcond
|
||||
|
||||
|
||||
|
||||
Binary file not shown.
|
Before Width: | Height: | Size: 46 KiB After Width: | Height: | Size: 51 KiB |
Loading…
Reference in New Issue
Block a user